SwipGuard

Safty Pressure Switch Type P1360

Date: August 2005

Sheet No.: 2-300GB

 

Application

Pressure Equipment Directive - PED

The European Community has decided to pass a set of rules called the Pressure Equipment Directive – PED.

These rules state that all kind of pressurised equipment must have a safty system that prevents the pressure to exceed the Max Allowable Operating Pressure that the equipment has to be approved for.

In the past the way of preventing the pressure to rise was to either install a pressure relief valve or a pressure bypass valve!

 

Now…

 

TEMPRESS has developed a new device – SwipGuard - that can be installed in the process line and give a emergency signal to either a pump or an electrical bypass valve.

The SwipGuard has been tested and approved according to the requirements in the Standard by TÜV.

 

 

 

SwipGuard acts as an ordinary switch in the security circuit and are set to break the circuit by a preset pressure.

SwipGuard has an internal detector to survey weather the bellow is leaking.  If so the sensor will give a signal that can operate a surveillance system in a PLC or PC monitoring.

The TEMPRESS SwipGuard Type P1360 is designed to meet the new PED zone I, II, III and IV requirements for emergency surveillance in pressurised piping systems.

The TEMPRESS SwipGuard is available in an industrial version for direct mounting by thread and in a special hygenic version with diaphragm seal for sanitary industries. Which allow it to be used for all kind of process equipment.

The TEMPRESS SwipGuard system Type P1360 consists of two independent and redundant switches.

 

                                                                                      

 

 

The Chemical Industry:

The SwipGuard can as well be used with great advantage as all kind of diaphragm seals can be mounted to withstand a chemical attack.

At the same time it is possible to mount the SwipGuard with a cooling tower so almost any temperature in the process can be handled.

 

The heating and boiler Industry:

SwipGuard can be equipped with a remote capillary pipe so the radiation and environment temperature will not harm the device

 

 

 

                                                                                      

 

 

Food and drug Industry:

The SwipGuard are developed in the background of wishes from the dairy-equipment producers, as spillage during processing is a major problem that occurs when using pressure relief valves or a sprin clap.

 

When using SwipGuard all kind of diaphragm seals can be mounted so the necessary hygienic cleaning process is easily done.

 

Using the SwipGuard in the food and drug industry where all kind of fluids are processed the same high security are achieved and an efficient cleaning process can be utilized.

 

 

 

                     

                        

                            

 
P1360 SPECIFICATIONS
Standard ranges

1 - 10 bar, 5-35 Bar

Repeatability
± 0.5% FS (typ.) ± 1% FS (max.allowable)
Response time
< 4 ms
Max. switch frequency
30/min. (0.5 Hz)
Mechanical Electrical at max. contact load > 100.000 cycles at 70 °C > 1.000,000 cycles
Max. operating pressure Test pressure Burst pressure 10 bar 15 bar > 40 bar
Electrical specifications
Switches Contact arrangement SPDT
DC resistive DC inductive NPN 5 A, 24V 4 A, 24V max 100 MA, 24 V
Mechanical specifications
Pressure connection Chemical seal
Electrical connection Plug DIN 43650-A, Pg 9 / Pg 11 / 13.5
Housing Diaphragm Bellow O-ring Diaphragm AISI 316 FPM Bronce NBR or FPM AISI 316
Housing Plug fixture Anodized AIMgSi Glass filled polyamid, PA 6.6
Weight
0.4 kg

Environmental conditions
Tempreature Operation Transport Only with liquid -10 to + 70°C -40 to + 90°C
Enclosure
IP 65, IEC 529
Vibration stability Sinusoidial 4 g, 25 Hz – 100 Hz IEC 60068-2-6
Hysteresis Typical 5-10 %
Not less than 3% T20 Not less than 5% T70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 