Diffrential Pressure Switch

Type P1133

Date: June 2005

Sheet No.: 1-43GB

               

Differential Pressure Gauges with contacts

Strong and cost effective instrument in the well proved Tempress Standard Line.

High repeatability of the switching point

• Adjustable contact function

• Easy installation

The Tempress Differential Pressure Gauges is a combination of the indicating and switching instrument for differential pressure measurement.

The instrument is based on a strong and well proved diaphragm movement for heavy duty areas. The instrument is designed for simple reading and operation.

The Tempress standard line products are cost effective and reliable products that are suitable for using in most industrial applications.

 

 

 

 

 

Tempress reserves the right to changes without notice

Specifications
Gauges: DN100
Case material: Stainless Steel
Cover: Macrolon
Ranges: 0-250 mbar to 0-25 bar
Max Static Pressure: 25 bar
Max. pressure load One-sided overpressure protected up to nominal pressure on both side of diaphragm, partial vacuum protected.
Ambient temp. -20 - +60 °C
Media temp. max. 60 °C
Protection IP54 acc. To DIN40050
Mounting Vertical, connection downwards
Accuracy ±2,5% of full scale
Zero adjustment Located on dial
Switching element: 2 mikroswitches with external adjustment
Adjustment: App. 5% of full scale range
Hysteresis: App. 2,5% of full scale
Load: U~max=250V AC, Imax=5 A, Pmax=250 VA
U=max=30 V DC, Imax=0,4 A, Pmax=10 W
Connection Pressure: 1/4" BSP male, others on request
Electrical: Plug or cable
Option: Chemical seals, ask Tempress sales.